| Sign In | Join Free | My brakesband.com |
|
Model Number : AG-CEMS09
SO2 Range : 0-100mg/m3 OEM
Response Time : ≤120S
Linearity Error : ≤±2%F.S.
O2 Range : 0-25%
Place of Origin : Nanjing, China
Brand Name : JUGE
Certification : IOS9001, CE
Payment Terms : T/T,Online order
Repeatability : ≤2%
Supply Ability : 100 Unit/Week
Price : USD10000-20000
Delivery Time : 10-15 working days
NO Range : 0-100mg/m3 OEM
Packaging Details : Neutral carton
MOQ : 1 Unit
NO2 Range : 0-100mg/m3 OEM
Product name : CEMS for SO2 NO NO2
This Continuous Emission Monitoring System (CEMS) monitors real-time concentrations of particulate matter and gaseous pollutants in exhaust gases from fixed pollution sources including boilers, industrial furnaces, and incinerators. The system is specifically designed for high-humidity, low-concentration environments.
The CEMS consists of three main components: the gaseous pollutant monitoring unit (SO2, NO, NO2), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.
Sample gas passes through a high-temperature heating pipeline, is filtered by a two-stage dust filter, and directly enters the gas chamber in the analyzer. The gas chamber is placed inside a high-temperature box and connected via UV fiber optics to a UV differential analyzer for precise flue gas measurement.
| Gaseous Pollutants | |
|---|---|
| SO2 | (0~200) mg/m³, customizable range |
| NO | (0~200) mg/m³, customizable range |
| NO2 | (0~200) mg/m³, customizable range |
| O2 | (0~25)% |
| Repetitiveness | ≤2% |
| 24h zero drift and range drift | ≤±2% f.s. |
| One-week zero-point drift and range drift | ≤±3% f.s. |
| Linear error | ≤±2% f.s. |
| Response time | ≤120s |
| Flue Gas Parameters | ||
|---|---|---|
| Temperature | Measuring range | (0~300) ºC, customizable |
| Accuracy | ≤±3℃ | |
| Pressure | Measuring range | (-10~10) kPa |
| Accuracy | ≤0.5% | |
| Velocity of flow | Measuring range | (0~40) m/s, (0~2) kPa, output optional |
| Accuracy | ≤±2% | |
| Humidity | Measuring range | (0~40) vol% |
| Accuracy | ≤±2% | |
| O2 | Measuring range | (0~25)% |
| Accuracy | ±2% | |
| Data Acquisition and Processing | |
|---|---|
| Data transmission module | 8-way analog input, 1-channel RS485 communication interface |
| IPC | 6-way RS232 communication interface, Windows operating system |
| Operational software | Flue gas emission monitoring software monitor |
| Power Supply | AC 220V, 50Hz, ≤7kW |

|
|
High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer Images |